- About
- Network
- News
- Initiatives
- Events
- Publications
- Blog
CENIC employs many automated network management tools to assist our Associates in the planning and management of their own networks, including Intermapper, RT, and Cricket, all of which can be found through Real-time Management Tools.
Function | Name | Example | Model | Notes |
Core routing | site-CORE or site-CORE{1,2} | RIV-CORE | Cisco CRS-1 | Backbone circuits only, no customer-facing connections |
High-speed aggregation | site-AGG{1,2} | FRG-AGG1 | Cisco GSR | |
Low-speed aggregation | site-AGG3 | OAK-AGG3 | Cisco 7200 | T-1, some T-3 circuits |
ISP transit | site-ISP or site-ISP{1,2,…} | SVL-ISP | Cisco GSR | ISP transit links and dedicated transit waves |
Peering | site-PX or site-PX{1,2,.} | LAX-PX1 | Cisco GSR | older documentation referred to these as -PEER |
In the following syntax:
[remote-device | TID | "EGM"]
is used to denote that one of the above is used as the first term:
remote-deviceTIDEGM
Note that [ ] are used to group options for terms while | is used to indicate options. These symbols are not used in the actual descriptions that we apply to the equipment.
Device names are in lower case. Campus names are in mised case or upper case as appropriate. Only certain characters are permitted: alphanmeric, /, -
[remote-device | TID | "EGM"] [Int | 15808-Int | CID] [Campus] [DF | EGM] [ISP | DC | HPR | DC/ISP]
[remote-device | TID | "EGM"] [Int | 15808-Int | CID] [layer-3 Device] [layer-3 Int]
For interfaces with subinterfaces, the information is split. The layer-2 information is listed on the main interface:
[remote-device | TID | "EGM"] [Int | 15808-Int | CID]
Repeat the layer-2 information, and provide the remaining information in the subinterface:
Campus:
[remote-device | TID | "EGM"] [Int | 15808-Int | CID] [Campus] [DF | EGM] [ISP | DC | HPR | DC/ISP]
Backbone:
[remote-device | TID | "EGM"] [Int | 15808-Int | CID] [layer-3 Device] [layer-3 Int]
Device DNS name: short DNS name:
e.g.: lax-15540-1
TID: 15808 TID
e.g.: LAXPL03
Int: interface:
e.g.: Gi1/1/0
15808-Int: rack/subrack/slot-[TT|BT] channel:
e.g.: 1/1/2-TT56
CID: last 4 digits of the EGM circuit ID
Campus: short name of campus:
e.g.: UCLA, San Diego CC, San Diego COE
Layer-2-device: backbone router at layer 3:
e.g.: svl-dc1
Layer-3-int: interface of remote layer-3 devices:
e.g.: Po1/0
Interface descriptions are revealed in many places:
sh ing description
Circuit IDs are sensitive information. Therefore, CENIC does not include them interface descriptions, as they may be unintentionally revealed if they are available in description fields.